Description

Phenolic novolac solution in ethylene glycol

Application

PF8593FL01 is used in refractory applications

Typical Properties

Property Standard Value Unit Test Method
Free Phenol Content GC max 2.0 %
Höppler Viscosity at 20°C 600 – 800 mPa·s
Solids Content at 135°C 50.5 – 54.5%

Tests are made in accordance with the current Hexion Standard Test Method and are available upon request. The typical properties provided are examples of product attributes and may not be tested.