Description

EPIKOTE™ Resin 807 + EPIKURE™ Curing Agent 866/S + EPIKURE™ Catalyst 03832 is a three component epoxy system for liquid injection moulding and other casting technologies with a Tg in the 105 – 115 °C range . As a result of its chemical composition, the system has advantageous processing properties, and also very good mechanical, electrical and thermal characteristics.

EPIKOTE™ Resin 807 + EPIKURE™ Curing Agent 866/S + EPIKURE™ Catalyst 03832 is ideal for use in moulding components of electrical equipment such as power, current and voltage transformers, conduits, post insulators and circuit breaker parts for medium and high voltage use.

EPIKOTETM Resin 807

100.0     pbw

EPIKURETM Curing Agent 866/S

  80.0     pbw

EPIKURETM Catalyst 03832

2.0 - 3.0 pbw

Benefits

  • No postcuring required
  • Short Curing Time
  • Industrial Pressure Gelation
  • Resin with Toughening Modifiers Resulting in Excellent Crack Resistance
  • Low Viscosity
  • Long Potlife at 25 – 40 C
  • Low Shrinkage

Sales Properties

EPIKOTETM Resin 807

Unit

Value

Test Method / Standard

Viscosity at 25 °C

mPa·s

9000 - 12000

DIN 53019

Epoxy number

%

22.9 – 23.9

DIN 16945

Epoxy equivalent *

g/equiv.

180 - 188

DIN 16945

Density at 20°C *

g/cm3

1.14 – 1.18

 DIN EN ISO 2811-2

*typical property

 

EPIKURETM Curing Agent 866/S

Unit

Value
Test Method /
Standard

Viscosity at 25 °C

mPa·s

55 - 75

 DIN 53015

Weight equivalent*

g/equiv.

166

 DIN 16945

Refractive index at 25 °C

 

1.495 – 1.499

Similar to DIN 51423-2

Density at 20°C

g/cm3

1.19 - 1.23

 DIN EN ISO 2811-2

Color Gardner

 

0 - 2

 DIN ISO 4630

*typical property

 

 

EPIKURETM Catalyst 03832

Unit

Value
Test Method /
Standard

Viscosity at 25 °C

mPa·s

15 - 45

DIN 53015

Refractive index at 25 °C

 

1.471 -  0.015

Similar to DIN 51423-2

Density at 20°C*

g/cm3

1.013 – 1.015

 DIN EN ISO 2811-2